Digital Multimeter APPA 505

Tidak Ada Stock

Spesifikasi Produk Digital Multimeter APPA 505 :

SKU : APPA 505

Size : 200 x 96 x 52 mm

Digital Multimeter APPA 505

Dapatkan produk APPA dengan harga terbaik hanya di alatproyek.com / hubungi 021-29986622 s/d 24, 081808090252

Deskripsi Produk Digital Multimeter APPA 505 :

Digital Multimeter APPA 505

Spesifikasi Detail Digital Multimeter APPA 505:

oltage DC  
  APPA 503 
  Range:                                               40mV~1000V
  Resolution:                                       0.001mV
  Basc Accuracy:                               +/-(0.03%+2d) 
  
  APPA 505
  Range:                                                100mV~1000V
  Resolution:                                        0.001mV
  Basic Accuracy:                              +/-(0.015%+2d)
 
  Input Impedance:                            10MOhm
  Overload Protection                       1000Vrms
 Voltage AC  
  APPA 503 
  Range:                                               40mV~1000V
  Resolution:                                       0.001mV
  Basc Accuracy:                               +/-(0.70%+5d) 
  
  APPA 505
  Range:                                                100mV~1000V
  Resolution:                                        0.001mV
  Basic Accuracy:                              +/-(0.40%+5d)
 
  Input Impedance:                            10MOhm//<100pF
  Overload Protection                       1000Vrms
 
  Conversion Type:                             AC+DC True RMS indicating
 
 Voltage (AC+DC)  
  APPA 503 
  Range:                                               40mV~1000V
  Resolution:                                       0.001mV
  Basc Accuracy:                               Same as ACV + 1.0%
  
  APPA 505
  Range:                                                100mV~1000V
  Resolution:                                        0.001mV
  Basic Accuracy:                              Same as ACV + 1.0%
 
  Input Impedance:                            10MOhm//<100pF
  Overload Protection                       1000Vrms
 
  Conversion Type:                             AC+DC True RMS indicating
 
 Current DC  
  APPA 503 
  Range:                                               4mA~40mA/10A
  Resolution:                                       0.1uA
  Basc Accuracy:                               +/- (0.20%+4d) 
  
  APPA 505
  Range:                                                10mA~100mA/10A
  Resolution:                                        0.1uA
  Basic Accuracy:                              +/- (0.10%+4d)
 
  Input Protection:                             440mA/1000V & 11A/1000V
                                                              DC/AC high energy fuse 
 
 Current AC  
  APPA 503 
  Range:                                               4mA~40mA/10A
  Resolution:                                       0.1uA
  Basc Accuracy:                               +/- (0.80%+8d) 
  
  APPA 505
  Range:                                                10mA~100mA/10A
  Resolution:                                        0.1uA
  Basic Accuracy:                              +/- (0.70%+8d)
 
  Input Protection:                             440mA/1000V & 11A/1000V
                                                              DC/AC high energy fuse
 
 Current (AC+DC)  
  APPA 503 
  Range:                                               4mA~40mA/10A
  Resolution:                                       0.1uA
  Basc Accuracy:                               Same as ACA + 1.0%
  
  APPA 505
  Range:                                                10mA~100mA/10A
  Resolution:                                        0.1uA
  Basic Accuracy:                              Same as ACA + 1.0%
 
  Input Protection:                             440mA/1000V & 11A/1000V
                                                              DC/AC high energy fuse
 
 Resistance  
  APPA 503 
  Range:                                               400Ohms~40MOhms
  Resolution:                                       0.01Ohms
  Basc Accuracy:                               +/-(0.20%+2d) 
  
  APPA 505
  Range:                                                1000Ohms~10MOhms
  Resolution:                                        0.01Ohms
  Basic Accuracy:                              +/-(0.025%+2d)
 
  Overload Protection                       1000Vrms 
 Continuity Beeper   
  < 50Ohms, 2KHz tone buzzer
 
 Diode Test    
  Open circuit voltage: 3V
 
 Frequency Counter   
  APPA 503 & 505
  Range:                                               10Hz~4MHz
  Resolution:                                       0.001Hz
  Basc Accuracy:                               +/-(0.002%+1d) 
 
  
 %Duty Factor   
  APPA 503 & 505
  Range:                                               20%~80%
  Resolution:                                       0.1%
  Basc Accuracy:                               +/-6d(20Hz~10KHz, 5Vp-p)   
 
 Capacitance  
  APPA 503 
  Range:                                               40nF~40mF
  Resolution:                                       0.001nF
  Basc Accuracy:                               +/-(0.9%+2d) 
  
  APPA 505
  Range:                                                40nF~40mF
  Resolution:                                        0.001nF
  Basic Accuracy:                              +/-(0.8%+2d)
 
  Overload Protection                       1000Vrms
 Temperature  
  APPA 503 & 505
  Range:                                               -200~1200Celsius degree
  Resolution:                                       0.1Celsius degree
  Basc Accuracy:                               +/-(1.0%+1Celsius degree) 

Digital Multimeter APPA 505

Write Your Own Review