FITUR INTEGRATED TESTING AND MEASURING UNIT CONSTANT ISC2000:

  • Integrated System Calibrator With 40000 Counts
  • True RMS ±0.03% High Accuracy (DCV) Bench Top Testing And Calibrating Unit, High Accuracy Of The DMM Module"
  • Ideally Suited For Calibrating Handheld Analog/Digital Multimeters or Other Electrical Voltage/Current Panel Meters

Lebih detail

Rp‎ 18.700.000,00

Info lainnya

FITUR INTEGRATED TESTING AND MEASURING UNIT CONSTANT ISC2000:

  • Integrated System Calibrator With 40000 Counts
  • True RMS ±0.03% High Accuracy (DCV) Bench Top Testing And Calibrating Unit, High Accuracy Of The DMM Module"
  • Ideally Suited For Calibrating Handheld Analog/Digital Multimeters or Other Electrical Voltage/Current Panel Meters
  • Widely Used In A Workshop As A Repair Or Service Station For Various Electronics Equipments Or Field Instruments
  • With Its Integrated Adjustable And Fixed Power Supply, Frequency Counter And Function Generator Module, The ISC2000 Is Ideally Suited For Students In Electronic Workshop Environments Or Electronic Related Research Projects

 

DMM
FunctionRangeAccuracyResolution
AC Current400µA

±(0.8% rdg + 10 dgts) 40Hz ~ 1kHz

0.01µA
4mA0.1µA
40mA1µA
400mA10µA
20A±(1.0% rdg + 15 dgts) 40Hz ~ 1kHz1mA
AC Voltage400mV±(0.8% rdg + 10 dgts) 40 Hz ~ 1kHz
±(5.0% rdg + 15 dgts) 10kHz ~ 50kHz
0.01mV
4V±(0.8% rdg + 10 dgts) 40Hz ~ 1kHz
±(5.0% rdg + 15 dgts) 1kHz ~ 20kHz
0.01mV
40V1mV
400V10mV
750V±(1.0% rdg + 10 dgts) 40Hz ~ 1kHz
±(5.0% rdg + 15 dgts) 1kHz ~ 3kHz
0.1V
DC Current400µA±(0.1% + 3 dgts)0.01µA
4mA0.1µA
40mA1µA
400mA10µA
20A±(0.5% + 5 dgts)1mA
DC Voltage400mV±(0.03% + 3 dgts)0.01mV
4V0.1mV
40V1mV
400V10mV
1000V±(0.06% + 5 dgts)0.1V
Resistance400Ω±(0.1% + 10 dgts)0.01Ω
4kΩ0.1Ω
40kΩ±(0.1% + 5 dgts)
400kΩ10Ω
4MΩ100Ω
40MΩ±(0.5% + 10 dgts)1kΩ
Diode TestTest current 1mA
Continuity TestBuzzer sound when voltage is less than 80mV at test current 3 mA maximal (resistance < 40Ω)
Logic Test3 Logic Level (Rdy, Hi, --, Lo)

Frequency Counter
Measuring RangeChannel A : 1Hz ~ 20MHz
LED Display depending on gate time and input signal
At least 7 digits are display per each second of gate time
Channel B : 20MHz ~ 2.7GHz
Input SensitivityChannel A : 40mV RMS Sine Wave for 100mVpp
Channel B : 40mV RMS Sine wave for 20MHz ~ 1.3GHz
or 40mV RMS Sine wave for 1.3MHz ~ 2.7GHz.
Maximum Input VoltageChannel A : 35Vpp
Channel B : 3Vpp
Input ImpedanceChannel A : 1MΩ
Channel B : 50Ω
Selectable Time BaseChannel A and B are switch-selectable

Function Generator
Wave FormsSine, square, triangle, skewed sine, ramp, pulse, TTL level square
Frequency1 ~ 10MHz
VCF Voltage Level0 to 10 VDC
Output ImpedanceSelectable 50Ω ±10%, 600Ω ±10%
Output Amplitude2Vpp ~ 20Vpp (open load)
1Vpp ~ 10Vpp (50Ω load)
Sine WaveDistortion less than 1% (at 1kHz)
Square WaveSymmetry less than 1% (at 1kHz)
Rise and fall time less than 150nS (at 1kHz)
Triangle WaveLinearity less than 1% (up to 100kHz), 50% (100k ~ 200MHz)
TTL OutputRise and fall time less than 30nS (at 1kHz)
Output level > 3V

Power Supply
FunctionTerminal 1Terminal 2Terminal 3
Output Voltage0 ~ 30V5V fixed15V fixed
Output Current0 ~ 3A2A1A
Ripple1mV max2mV max2mV max
Output Current Max2A/3A2A (fold back)2A (fold back)
Display3½ digits

General Specifications
Power Source220/240VAC at 50 to 60Hz
SizeH6.5 x W14.5 x D12.5inch
Standard AccessoriesTest Leads, BNC Cable, Power Cable, AC/DC Adapter, R232C Cable with Software, Manual, Constant Certificate