Power Quality Analizer HIOKI PW3198-90

Ada Stock

Spesifikasi Produk Power Quality Analizer HIOKI PW3198-90 :

SKU : PW3198-90

Power Quality Analizer HIOKI PW3198-90

Dapatkan produk Hioki dengan harga terbaik hanya di alatproyek.com / hubungi 021-29986622 s/d 24, 081808090252

Contact Us
email: sales@alatproyek.com atau telepon: 021-29986622 s/d 24

Deskripsi Produk Power Quality Analizer HIOKI PW3198-90 :

Power Quality Analizer HIOKI PW3198-90

Fitur Power Quality Analizer HIOKI PW3198-90:

  • Basic accuracy voltage ±0.1% of nominal voltage
  • Transient overvoltage : 2MHz sampling
  • Real-time clock accuracy ±0.3 per day (with instrument on, 23°C±5°C (73°F±9°F)
  • Interface SD/SDHC card, RS-232C, LAN (HTTP server function), USB2.0

Spesifikasi Detail Power Quality Analizer HIOKI PW3198-90:

SPECIFICATIONS
Country of Origin -
Dimension -
Weight

-

Type PW3198-90
Measurement line type Single-phase 2-wire
Single-phase 3-wire
Three-phase 3-wire 
Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement)
Voltage ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current ranges 500.00 mA to 5.0000 kA AC (depends on each current sensors)
Basic accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy
Active power: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy
Measurement items
  • Transient overvoltage : 2MHz sampling.
  • Frequency cycle : Calculated as one cycle, 40 to 70Hz
  • RMS voltage/ RMS current refreshed each half-cycle
  • Voltage swell, Voltage dips, Voltage interruption
  • Inrush current
  • Voltage waveform comparison
  • Instantaneous flicker value: As per IEC61000-4-15
  • Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz
  • 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz
  • Voltage waveform peak, Current waveform peak
  • Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase)
  • High-order harmonic component (voltage/ current): 2kHz to 80kHz
  • Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50th orders
  • Harmonic voltage-current phase angle: 1th to 50th orders
  • Total harmonic distortion factor (voltage/ current)
  • Inter harmonic (voltage/ current): 0.5Hz to 49.5Hz
  • K Factor (multiplication factor)
  • IEC Flicker, Δ V10 Flicker
Record 55 weeks (with repeated recording set to [1 Week], 55 iterations)
35 days (with repeated recording set to [OFF])
Maximum recordable events 55,000 events (with repeated recording on)
1000 events (with repeated recording off)
Interface SD/SDHC card, RS-232C, LAN (HTTP server function), USB2.0
Display 6.5-inch TFT color LCD (640×480 dots)
Real-Time Clock function Auto-calendar, leap-year correcting 24-hour clock
Real-time clock accuracy ±0.3 per day (with instrument on, 23°C±5°C (73°F±9°F)
Power outage processing In the event of a power outage during recording, instrument resumes recording once the power is back on (integral power starts from 0).